EMC anechoic chambers

Previous
Next

Anechoic Chambers designed to meet EMC standards and requirements

For your radiated emission and immunity tests, we offer anechoic chambers that comply with regulations and standards applicable to the testing of equipment for domestic, commercial, aeronautical, defense, automotive, telecommunications and research laboratory use, such as CISPR, EN, MIL-STD, RTCA DO 160, ETSI …

Various models of chambers, semi or fully anechoic, meet the normative requirements:

  • For pre-qualification or qualification tests,
  • For high intensity radiated field (HIRF) tests.

The facility is defined according to the standards to be applied, whether it is a pre-qualification or qualification facility and the equipment to be tested. This approach allows us to consider your host building and budget constraints.

We are experienced and have numerous references of EMC chambers in France and internationally for all types of applications.

We also supply the anechoic chambers with :

  • Antenna positioner,
  • Turntable,
  • Video camera,
  • Fire detection/extinction,
  • Gas detection …

We can act as a single point of contact in the definition and supply of equipment (antenna positioners, turntable, fire detection, air conditioning …) and associated instrumentation (antennas, RF amplifiers, generators, receivers, field probes, software, cables …).

Our standard models of EMC anechoic chambers

We offer you models of standard EMC anechoic chambers according to the following international standards or their equivalents. Custom-made models are also possible.

Model Type CIVIL AUTOMOTIVE AERO / DEF ETSI External overall Dimensions L x l x h
CISPR16-1-4 EN61004-3 CISPR25 ISO 11452-2 MIL STD 461
EMI EMS EMI EMS DO 160
ARES 1F - (1m EMS/EMI) SAC C 4.70 x 3.70 x 2.60m
ARES 1P - (1m EMS/EMI) SAC C 5.00 x 4.15 x 3.00m
HERA 1F - (1m EMS/EMI) SAC PC C 5.00 x 3.15 x 2.60 m
HERA 3P - (3m EMS/EMI) SAC PC C 8.30 x 4.50 x 3.25 m
HERA 3F - (3m EMS/EMI) SAC PC C 7.95 x 3.40 x 3.25 m
HERMES 3 - (3m EMS/EMI) SAC C C C C C C 8,65 x 7.10 x 5,85 m
HERMES 5 - (3m EMS/5m EMI) SAC C C C C C C 12.30 x 8.80 x 6.95 m
HERMES 10 - (3m EMS/10m EMI) SAC C C C C C C 19.20 x 13.55 x 9.00 m
CHRONOS 1F - (1m EMS/EMI) SAC C C 5.65 x 4.15 x 3.25 m
ATHENA 3 - (3m EMS/EMI) FAC C C C C C C 8.40 x 4.80 x 4.50 m
Model ARES 1F - (1m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
CIVIL
EN61004-3
EMS
AUTOMOTIVE
CISPR25
EMI
AUTOMOTIVE
ISO 11452-2
EMS
AERO / DEF
MIL STD 461
DO 160
C
ETSI
External overall Dimensions L x l x h 4.70 x 3.70 x 2.60m
Model ARES 1P - (1m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
CIVIL
EN61004-3
EMS
AUTOMOTIVE
CISPR25
EMI
AUTOMOTIVE
ISO 11452-2
EMS
AERO / DEF
MIL STD 461
DO 160
C
ETSI
External overall Dimensions L x l x h 5.00 x 4.15 x 3.00m
Model HERA 1F - (1m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
PC
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
AUTOMOTIVE
ISO 11452-2
EMS
AERO / DEF
MIL STD 461
DO 160
ETSI
External overall Dimensions L x l x h 5.00 x 3.15 x 2.60 m
Model HERA 3P - (3m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
PC
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
AUTOMOTIVE
ISO 11452-2
EMS
AERO / DEF
MIL STD 461
DO 160
ETSI
External overall Dimensions L x l x h 8.30 x 4.50 x 3.25 m
Model HERA 3F - (3m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
PC
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
AUTOMOTIVE
ISO 11452-2
EMS
AERO / DEF
MIL STD 461
DO 160
ETSI
External overall Dimensions L x l x h 7.95 x 3.40 x 3.25 m
Model HERMES 3 - (3m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
C
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
C
AUTOMOTIVE
ISO 11452-2
EMS
C
AERO / DEF
MIL STD 461
DO 160
C
ETSI C
External overall Dimensions L x l x h 8,65 x 7.10 x 5,85 m
Model HERMES 5 - (3m EMS/5m EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
C
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
C
AUTOMOTIVE
ISO 11452-2
EMS
C
AERO / DEF
MIL STD 461
DO 160
C
ETSI C
External overall Dimensions L x l x h 12.30 x 8.80 x 6.95 m
Model HERMES 10 - (3m EMS/10m EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
C
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
C
AUTOMOTIVE
ISO 11452-2
EMS
C
AERO / DEF
MIL STD 461
DO 160
C
ETSI C
External overall Dimensions L x l x h 19.20 x 13.55 x 9.00 m
Model CHRONOS 1F - (1m EMS/EMI)
Type SAC
CIVIL
CISPR16-1-4
EMI
CIVIL
EN61004-3
EMS
AUTOMOTIVE
CISPR25
EMI
C
AUTOMOTIVE
ISO 11452-2
EMS
C
AERO / DEF
MIL STD 461
DO 160
ETSI
External overall Dimensions L x l x h 5.65 x 4.15 x 3.25 m
Model ATHENA 3 - (3m EMS/EMI)
Type FAC
CIVIL
CISPR16-1-4
EMI
C
CIVIL
EN61004-3
EMS
C
AUTOMOTIVE
CISPR25
EMI
C
AUTOMOTIVE
ISO 11452-2
EMS
C
AERO / DEF
MIL STD 461
DO 160
C
ETSI C
External overall Dimensions L x l x h 8.40 x 4.80 x 4.50 m

EMS = electromagnetic susceptibility

EMI = electromagnetic interference

SAC = Semi-anechoic chamber

FAC = Full anechoic chamber

C=Compliance

PC=Pre-compliance

Our assets

  • The ability to propose an anechoic chamber design adapted to each type of object to be tested,
  • An organization in project management mode putting the customer at the heart of the project,
  • An independent ISO17025 accredited measurement entity, at your disposal for the technical validation of the test equipment provided,
  • A production site with all the technical means and human resources (60 employees) required to manufacture high quality solutions,
  • A commitment to global performance.
For any request, send your specifications to sales@siepel.com